TEMPO | OPM520 & SLS520 (SINGLEMODE KIT, MSO, DUAL) | #SM DUAL KIT HP
TEMPO COMMUNICATIONS | PART #SM DUAL KIT HP
OPM520 & SLS520 (SINGLEMODE KIT, MSO, DUAL)
DESCRIPTION
The Tempo Communications optical power meters are available in standard and high-power versions for the Telco and MSO markets. Absolute and referenced power measurements ensure fast and accurate loss budget and insertion loss measurements. When placing tones on the fiber using a Tempo Communications source provides the optical power meter will definitively identify fiber optic cables.
The OPM510 and OPM520 supports calibrated wavelengths of 850, 980, 1270 1300, 1310, 1490, 1550, 1577, 1623 and 1650nm.
The Tempo Communications fiber optic sources are available in dual and triple wavelength lasers and a dual wavelength LED. Accurate insertion loss measurements are possible when used in conjunction with the Tempo Communications optical power meters. When placing tones on the fiber the Tempo Communications optical power meter will quickly identify the fiber.
The ruggedized IP54 compliant package provides test confidence when testing singlemode and multimode networks. See the Models tab for more details.
The Tempo Communications optical power meters and sources can be ordered in various kits for specific applications.
Various accessories such as optical adapters, power supply and carry cases that can be ordered separately.
OVERVIEW
- Dual and triple lasers available
- Out of band testing at 1625nm and 1650nm
- 270Hz, 1kHz and 2kHz tone
- PC flat polish interface
- Each source is supplied with one SC/PC adapter for each bulkhead
Using_the_fiberTOOLS_sources_and_detectors.pdf
Common Questions About the Tempo SM Dual Kit HP OPM520 and SLS520
What is the Tempo SM Dual Kit HP used for?
The Tempo SM Dual Kit HP is used to measure optical power and perform insertion loss testing on singlemode fiber optic networks using the OPM520 High Power Optical Power Meter and SLS520 Dual Laser Source.
What wavelengths does the SLS520 provide?
The SLS520 provides 1310 nm and 1550 nm laser wavelengths for testing, troubleshooting, and measuring insertion loss on singlemode fiber optic networks.
Can the SM Dual Kit HP be used for fiber identification?
Yes. The kit supports 270 Hz, 1 kHz, and 2 kHz tones that allow technicians to identify and trace individual fiber optic cables during testing.
At a Glance
• OPM520 High Power Optical Power Meter and SLS520 Dual Laser Source kit
• 1310 nm and 1550 nm source for singlemode fiber testing
• Supports optical power, loss, and fiber identification testing
• Rugged IP54 compliant equipment for field use